Kabel Gentian Optik Dalaman Penimbal Ketat Fanout Pengedaran (GJFJV)
Parameter Teknikal:
| Kabel Gentian Optik Dalaman Fanout (GJFJV) | Diameter kabel | Berat | |
| 2 teras | 4.5mm | 22.00kg/km | |
| 4 teras | 4.5mm | 22.00kg/km | |
| 6 teras | 4.5mm | 23.00kg/km | |
| 8 teras | 5.5mm | 27.00kg/km | |
| 10 teras | 5.5mm | 30.00kg/km | |
| 12 teras | 6.0mm | 35.00kg/km | |
| Suhu penyimpanan (℃) | -20+60 | ||
| Jejari Lenturan Min (mm) | Jangka panjang | 10D | |
| Jejari Lenturan Min (mm) | Jangka pendek | 20D | |
| Kekuatan Tegangan Min yang Dibenarkan (N) | Jangka panjang | 200 | |
| Kekuatan Tegangan Min yang Dibenarkan (N) | Jangka pendek | 600 | |
| Beban Remuk (N/100mm) | Jangka panjang | 200 | |
| Beban Remuk (N/100mm) | jangka pendek | 1000 | |
Ciri-ciri gentian:
| Gaya gentian | Unit | SMG652 | SMG652D | SMG657A | MM50/125 | MM62.5/125 | MMOM3-300 | ||
| keadaan | nm | 1310/1550 | 1310/1550 | 1310/625 | 850/1300 | 850/1300 | 850/1300 | ||
| pelemahan | dB/km | ≤0.36/0.23 | ≤0.34/0.22 | ≤.035/0.21 | ≤3.0/1.0 | ≤3.0/1.0 | ≤3.0/1.0 | ||
| Penyebaran | 1550nm | Ps/(nm*km) | ---- | ≤18 | ≤18 | ---- | ---- | ---- | |
| 1625nm | Ps/(nm*km) | ---- | ≤22 | ≤22 | ---- | ---- | ---- | ||
| Lebar jalur | 850nm | MHZ.KM | ---- | ---- | ≥400 | ≥160 | |||
| 1300nm | MHZ.KM | ---- | ---- | ≥800 | ≥500 | ||||
| Panjang gelombang serakan sifar | nm | ≥1302≤1322 | ≥1302≤1322 | ≥1302≤1322 | ---- | ---- | ≥ 1295,≤1320 | ||
| Cerun penyebaran sifar | nm | ≤0.092 | ≤0.091 | ≤0.090 | ---- | ---- | ---- | ||
| Serat Individu Maksimum PMD | ≤0.2 | ≤0.2 | ≤0.2 | ---- | ---- | ≤0.11 | |||
| Nilai Pautan Reka Bentuk PMD | Ps(nm2*km) | ≤0.12 | ≤0.08 | ≤0.1 | ---- | ---- | ---- | ||
| Panjang gelombang pemotongan gentian λc | nm | ≥ 1180≤1330 | ≥1180≤1330 | ≥1180≤1330 | ---- | ---- | ---- | ||
| Pemotongan kabelpanjang gelombang λcc | nm | ≤1260 | ≤1260 | ≤1260 | ---- | ---- | ---- | ||
| MFD | 1310nm | um | 9.2±0.4 | 9.2±0.4 | 9.0±0.4 | ---- | ---- | ---- | |
| 1550nm | um | 10.4±0.8 | 10.4±0.8 | 10.1±0.5 | ---- | ---- | ---- | ||
| BerangkaApertur (NA) | ---- | ---- | ---- | 0.200± 0.015 | 0.275±0.015 | 0.200±0.015 | |||
| Langkah (purata dwiarahpengukuran) | dB | ≤0.05 | ≤0.05 | ≤0.05 | ≤0.10 | ≤0.10 | ≤0.10 | ||
| Ketidakteraturan terhadap seratpanjang dan titik | dB | ≤0.05 | ≤0.05 | ≤0.05 | ≤0.10 | ≤0.10 | ≤0.10 | ||
| Ketakselanjaran | |||||||||
| Perbezaan serakan balikpekali | dB/km | ≤0.05 | ≤0.03 | ≤0.03 | ≤0.08 | ≤0.10 | ≤0.08 | ||
| Keseragaman pelemahan | dB/km | ≤0.01 | ≤0.01 | ≤0.01 | |||||
| Diameter teras | um | 9 | 9 | 9 | 50±1.0 | 62.5±2.5 | 50±1.0 | ||
| Diameter pelapisan | um | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | ||
| Pelapisan tidak berbentuk bulatan | % | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | ||
| Diameter salutan | um | 242±7 | 242±7 | 242±7 | 242±7 | 242±7 | 242±7 | ||
| Salutan/serakralat sepusat | um | ≤12.0 | ≤12.0 | ≤12.0 | ≤12.0 | ≤12.0 | ≤12.0 | ||
| Salutan bukan bulatan | % | ≤6.0 | ≤6.0 | ≤6.0 | ≤6.0 | ≤6.0 | ≤6.0 | ||
| Ralat konsentrisiti teras/salut | um | ≤0.6 | ≤0.6 | ≤0.6 | ≤1.5 | ≤1.5 | ≤1.5 | ||
| Keriting (jejari) | um | ≤4 | ≤4 | ≤4 | ---- | ---- | ---- | ||
Pembinaan Kabel:
Pemotongan Kabel:
Kabel OM3 8 teras berbilang mod
Kabel 4 teras mod tunggal
Kabel Multimod 50/125 24 teras
Huraian:
•Kabel Optik Gentian Optik Dalaman Penimbal Ketat Fanout Pengedaran menggunakan 2~48 teras (atau lebih) menggunakan gentian penimbal ketat 900μm atau 600μm sebagai subkabel optik. Biasanya ia meliputi penggunaan PVC atau LSZH, juga menggunakan PE atau Nilon.
•Serat penimbal ketat dibalut dengan lapisan benang aramid sebagai anggota kekuatan, kemudian dilengkapi dengan lapisan bahan PVC atau LSZH sebagai jaket luar.
•Warna jaket keluar Kabel Gentian Optik Dalaman Penimbal Ketat Fanout Pengedaran:
Mod tunggal: Kuning,
Mod Berbilang OM1 / OM2: Jingga,
Mod Berbilang OM3 / OM4: Air,
Mod Berbilang OM4: Ungu,
Mutimode OM5: Kapur.
Warna lain adalah pilihan.
Permohonan:
+ Digunakan dalam kuncir dan tali tampalan.
+ Digunakan sebagai talian sambung peralatan, dan digunakan dalam sambungan optik dalam optikbilik komunikasi, pusat data dan bingkai pengedaran optik.
+ Digunakan dalam pemasangan kabel dalaman, terutamanya digunakan sebagai kabel pengedaran.
Ciri-ciri:
•Ciri-ciri mekanikal dan persekitaran yang baik.
•Ciri-ciri kalis api memenuhi keperluan piawaian yang berkaitan.
•Ciri-ciri mekanikal jek memenuhi keperluan piawaian yang berkaitan.
•Lembut, fleksibel, mudah diletakkan dan disambungkan, dan dengan penghantaran data berkapasiti besar.
•Memenuhi pelbagai keperluan pasaran dan pelanggan.
Aplikasi: digunakan untuk kabel dalaman kipas keluar berbilang gentian pigtail/kord tampalan
+ Digunakan dalam kuncir dan tali tampalan.
+ Digunakan sebagai talian sambung peralatan, dan digunakan dalam sambungan optik dalam optik
bilik komunikasi dan bingkai pengedaran optik.
+ Digunakan dalam pemasangan kabel dalaman, terutamanya digunakan sebagai kabel pengedaran.
Pembungkusan: