Kabel Gentian Optik Dalaman Penampan Ketat Fanout (GJFJV)
Parameter Teknikal:
| Kabel Gentian Optik Dalaman Fanout (GJFJV) | Diameter kabel | Berat badan | |
| 2 teras | 4.5mm | 22.00kg/km | |
| 4 teras | 4.5mm | 22.00kg/km | |
| 6 teras | 4.5mm | 23.00kg/km | |
| 8 teras | 5.5mm | 27.00kg/km | |
| 10 teras | 5.5mm | 30.00kg/km | |
| 12 teras | 6.0mm | 35.00kg/km | |
| Suhu penyimpanan (℃) | -20+60 | ||
| Jejari Lentur Min(mm) | Jangka panjang | 10D | |
| Jejari Lentur Min(mm) | Jangka pendek | 20D | |
| Kekuatan Tegangan minimum (N) yang dibenarkan | Jangka panjang | 200 | |
| Kekuatan Tegangan minimum (N) yang dibenarkan | Jangka pendek | 600 | |
| Beban Hancur (N/100mm) | Jangka panjang | 200 | |
| Beban Hancur (N/100mm) | jangka pendek | 1000 | |
Ciri gentian:
| Gaya gentian | Unit | SMG652 | SMG652D | SMG657A | MM50/125 | MM62.5/125 | MMOM3-300 | ||
| syarat | nm | 1310/1550 | 1310/1550 | 1310/625 | 850/1300 | 850/1300 | 850/1300 | ||
| pengecilan | dB/km | ≤0.36/0.23 | ≤0.34/0.22 | ≤.035/0.21 | ≤3.0/1.0 | ≤3.0/1.0 | ≤3.0/1.0 | ||
| Penyerakan | 1550nm | Ps/(nm*km) | ---- | ≤18 | ≤18 | ---- | ---- | ---- | |
| 1625nm | Ps/(nm*km) | ---- | ≤22 | ≤22 | ---- | ---- | ---- | ||
| Lebar jalur | 850nm | MHZ.KM | ---- | ---- | ≥400 | ≥160 | |||
| 1300nm | MHZ.KM | ---- | ---- | ≥800 | ≥500 | ||||
| Panjang gelombang penyebaran sifar | nm | ≥1302≤1322 | ≥1302≤1322 | ≥1302≤1322 | ---- | ---- | ≥ 1295,≤1320 | ||
| Cerun serakan sifar | nm | ≤0.092 | ≤0.091 | ≤0.090 | ---- | ---- | ---- | ||
| Serat Individu Maksimum PMD | ≤0.2 | ≤0.2 | ≤0.2 | ---- | ---- | ≤0.11 | |||
| Nilai Pautan Reka Bentuk PMD | Ps(nm2*km) | ≤0.12 | ≤0.08 | ≤0.1 | ---- | ---- | ---- | ||
| Panjang gelombang potong gentian λc | nm | ≥ 1180≤1330 | ≥1180≤1330 | ≥1180≤1330 | ---- | ---- | ---- | ||
| Potongan kabelpanjang gelombang λcc | nm | ≤1260 | ≤1260 | ≤1260 | ---- | ---- | ---- | ||
| MFD | 1310nm | um | 9.2±0.4 | 9.2±0.4 | 9.0±0.4 | ---- | ---- | ---- | |
| 1550nm | um | 10.4±0.8 | 10.4±0.8 | 10.1±0.5 | ---- | ---- | ---- | ||
| berangkaApertur(NA) | ---- | ---- | ---- | 0.200± 0.015 | 0.275±0.015 | 0.200±0.015 | |||
| Langkah (min dua arahukuran) | dB | ≤0.05 | ≤0.05 | ≤0.05 | ≤0.10 | ≤0.10 | ≤0.10 | ||
| Penyimpangan terhadap seratpanjang dan titik | dB | ≤0.05 | ≤0.05 | ≤0.05 | ≤0.10 | ≤0.10 | ≤0.10 | ||
| Ketaksinambungan | |||||||||
| Perbezaan backscatterpekali | dB/km | ≤0.05 | ≤0.03 | ≤0.03 | ≤0.08 | ≤0.10 | ≤0.08 | ||
| Keseragaman pengecilan | dB/km | ≤0.01 | ≤0.01 | ≤0.01 | |||||
| Diameter teras | um | 9 | 9 | 9 | 50±1.0 | 62.5±2.5 | 50±1.0 | ||
| Diameter pelapisan | um | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | ||
| Pelapisan bukan pekeliling | % | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | ||
| Diameter salutan | um | 242±7 | 242±7 | 242±7 | 242±7 | 242±7 | 242±7 | ||
| Salutan/chaffinchralat secara konsentrik | um | ≤12.0 | ≤12.0 | ≤12.0 | ≤12.0 | ≤12.0 | ≤12.0 | ||
| Salutan bukan pekeliling | % | ≤6.0 | ≤6.0 | ≤6.0 | ≤6.0 | ≤6.0 | ≤6.0 | ||
| Ralat ketumpuan teras/pelapisan | um | ≤0.6 | ≤0.6 | ≤0.6 | ≤1.5 | ≤1.5 | ≤1.5 | ||
| Curl(radius) | um | ≤4 | ≤4 | ≤4 | ---- | ---- | ---- | ||
Pembinaan Kabel:
Potongan Kabel:
Multimod OM3 8 teras Kabel
Mod tunggal 4 teras Kabel
Multimod 50/125 24 teras Kabel
Penerangan:
•Kabel Fiber Optik Dalaman Penampan Fanout Tight Buffer menggunakan 2~48 teras (atau lebih) menggunakan gentian penimbal ketat 900μm atau 600μm sebagai kabel sub optik. Biasanya ia meliputi penggunaan PVC atau LSZH, juga menggunakan PE atau Nilon.
•Gentian penampan yang ketat dibalut dengan lapisan benang aramid sebagai anggota kekuatan, kemudian dilengkapkan dengan lapisan bahan PVC atau LSZH sebagai jaket keluar.
•Warna jaket Pengedaran Fanout Ketat Penampan Kabel Gentian Optik Dalaman:
Mod tunggal: Kuning,
Multimod OM1 / OM2: Jingga,
Multimod OM3 / OM4: Aqua,
Multimod OM4: Violet,
Mutimode OM5: Limau nipis.
Warna lain adalah pilihan.
Permohonan:
+ Digunakan dalam pigtails dan kord tampalan.
+ Digunakan sebagai talian sambungan peralatan, dan digunakan dalam sambungan optik dalam optikbilik komunikasi, pusat data dan bingkai pengedaran optik.
+ Digunakan dalam kabel dalaman, terutamanya digunakan sebagai kabel pengedaran.
Ciri-ciri:
•Ciri mekanikal dan persekitaran yang baik.
•Ciri kalis api memenuhi keperluan piawaian yang berkaitan.
•Ciri-ciri mekanikal jacked memenuhi keperluan piawaian yang berkaitan.
•Lembut, fleksibel, mudah diletakkan dan disambungkan, dan dengan penghantaran data berkapasiti besar.
•Memenuhi pelbagai keperluan pasaran dan pelanggan.
Permohonan: digunakan untuk kabel dalaman kipas keluar berbilang gentian pigtail/ kord tampalan
+ Digunakan dalam pigtails dan kord tampalan.
+ Digunakan sebagai talian sambungan peralatan, dan digunakan dalam sambungan optik dalam optik
bilik komunikasi dan bingkai pengedaran optik.
+ Digunakan dalam kabel dalaman, terutamanya digunakan sebagai kabel pengedaran.
Pembungkusan: